As liquid level rises up to a set point,
a level switch on the bilge well is actuated.
The alarm signal is given to the bilge alarm
panel through I.S barrier, and the audible and
visual alarm on the alarm panel will be operated. |
|
|
|
|
|
Power Source : AC 110V/220V, 60Hz OR DC24V
Output : Visiable & Audible Alarm
Connection Size : JIS
Setting Accuracy : ¡¾5mm
Setting Point : 120 ¡ 5000mm
Max. Working Press. : 5Kg/§²
Min. Sp. Gr : 0.85
Contact Rating : 250VAC, 0.5A
IP Rating : IP 56(Option 67)
|
|
|
|
|
|
|
Reed switch type level switch / LS-TM Contact : SPST
Switch rating : AC 250V/15A , DC 30V/6A
Max. Working press. : 5 Kg/§²
IP Rating : IP 56, IP67(option)
Connect Size : 5K65A, 5K80A, 5K100A
Material - Housing : ALDC, BSBM, ALC
Flange : SS400, SUS304
Float : SUS316, Synthetic Rubber |
|
|
Capacitance type level switch / DLS-75P Contact : SPDT
Switch rating : AC 110V/220V, DC 30V/6A
Max. Working temp. : -25 ~ +100¡É
IP Rating : IP 56, IP67(option)
Connect Size : 5K65A, 5K80A, 5K100A, PT1¡±,
PT1 1/2¡±
Material - Terminal box. Housing : Ac,SUS316L
- Flange : SS400,SUS304
- Insulation : Tefron
- Enclosure : Ip67 |
|
|
Displase type level switch / DM-90A-1F Contact : SPDT, DPDT
Switch rating : AC 250V/15A, DC 30V/6A
Max. temp. : 180¡É
IP Rating : IP 56, IP67(option)
Connect Size : 5K100A (STD.)
Material - Body, Cover : ALC, SS400
- Flange : SS400,SUS304
- Displacer : SUS304
- Guide pipe : SUS304
|
|
|
|
|
|
|
|
|
BR : BILGE ROOM
PR : PUMP ROOM
BZ : BUZZER
BS : BUZZER STOP |
|
|
|